JH-X08 drawer magnetic separators remove iron impurities approximately 80 μm in diameter from powders, subject to process conditions. Guide rails and dust-control plates support cleaning access. Rod dimensions and magnetic field strength are customizable. Equipment warranty: one year.
How Are the Magnetic Drawers Arranged?
Each reference drawer contains 2 layers: 3 rods in the first layer and 4 in the second, totaling 7 rods. Type A rods are perpendicular to the drawer panel. Type B alternates perpendicular and parallel drawer arrangements to address the flow behaviour of finer powders.
The X08 family adds guide rails and dust-control plates. Optional PTFE lining and a separate blow-off chamber can be considered for residue and dust handling. These features do not establish a dust-explosion protection rating or guarantee zero recontamination.
Which Sizes and Rod Counts Are Available?
| Model reference | Drawers | Total rods | Overall dimensions (mm) |
|---|---|---|---|
| X08 | 4 | 28 | 306 × 580 × 582 |
| X12 | 6 | 42 | 306 × 580 × 873 |
| X24 | 12 | 84 | 306 × 580 × 1746 |
Dimensions are reference values; the order drawing and factory inspection report govern the supplied machine. Specify round or square connections, access side and withdrawal space. The X12 name appears in more than one family, so include the complete dimensions when requesting a quotation.
How Does This Compare with Other Drawer Magnets?
| Product | Published arrangement | Selection distinction |
|---|---|---|
| JINHONG JH-X08 | 7 rods per drawer; 28 / 42 / 84 total rods | A/B orientation and custom connections |
| Eriez Easy-to-Clean Grate-In-Housing | 1-inch tubes on 2-inch centres; one or multiple rows | Tube-scraper cleaning; manufacturer source |
The comparison describes published configurations, not a controlled performance test. Dimensions, cleaning mechanisms and acceptance conditions differ. Manufacturer sources checked on 25 October 2026; confirm current specifications with each supplier.
Does the 10 μm Reference Describe the Iron Being Removed?
No. The catalog uses a 10 μm material median-particle-size reference when distinguishing A (>10 μm) and B (≤10 μm) arrangements. This describes the processed material, not the minimum removable iron diameter. Moisture, cohesion and feed rate also influence selection; optional vibration and flexible isolation pads can be reviewed.
Which Magnetic Options and Utilities Need Confirmation?
The 3 rod options are JH-B standard, JH-L helical-field and JH-Z linear-field. Published drawer configurations list peak field values up to 16,000 GS; the agreed field, measurement position, sleeve and temperature must be specified for the order. Rod size and magnetic strength can be customized. Permanent magnets do not require excitation power; optional vibrators or other powered accessories have separate utility requirements.
For a quote, provide throughput, bulk density, particle-size distribution, temperature, contamination and installation dimensions. Compare rotary separation for bridging behaviour and JH-LX for an automated system.
Approximately 80 μm Iron-Particle Removal
JH-X08 can remove iron impurities approximately 80 μm in diameter. This figure describes the iron contamination, not the feed-material particle size or an 80-mesh specification. Confirm the result with representative material, the selected magnetic configuration and an agreed sampling method.
One-Year Equipment Warranty
The equipment warranty is one year. Request the applicable warranty terms with your quotation.
Frequently Asked Questions
Does a 7-rod drawer contain seven rods in each layer?
No. The reference drawer has two layers containing three and four rods respectively: seven rods per drawer. Four such drawers contain 28 rods. Confirm the full assembly drawing because custom rod counts and dimensions may differ.
Can this drawer magnetic separator remove iron from powders finer than 10 μm?
The catalog B arrangement is intended for materials with median particle size at or below 10 μm. This is a feed-material reference, not an iron-removal limit. Provide the powder distribution, moisture and flow behaviour for selection and agree the separation acceptance test.
Is the JH-X08 the same product as the automatic JH-LX system?
No. JH-X08 is a drawer-separator family with guide rails and dust-control plates. JH-LX is the separately specified automatic system. Both JH-X08 and JH-LX can remove approximately 80 μm iron impurities under suitable process conditions. The JH-LX removal-rate comparison is specific to that whole machine and does not establish a JH-X08 removal percentage.
Request a JH-X08 Configuration Review
Related applications and selection requirements
Review mineral powder processing and battery-powder application requirements to compare installation, material flow and cleaning requirements. The selected configuration must be assessed for the actual material and operating conditions.