JH-X drawer magnetic separators capture ferromagnetic contamination from gravity-fed powders and granules. Reference housings contain 4, 6 or 12 drawers, totaling 28, 42 or 84 rods. Select the A or B arrangement, rod configuration and housing size for the material flow and installation.
How Are the Magnetic Drawers Arranged?
Each reference drawer contains 2 layers: 3 rods in the first layer and 4 in the second, totaling 7 rods. Type A rods are perpendicular to the drawer panel. Type B alternates perpendicular and parallel drawer arrangements to address the flow behaviour of finer powders.
Stainless steel housings are listed, with nylon or PP alternatives on request. Flow-guide wedges between rod layers are intended to reduce material bypass along the housing wall. Confirm wear, material compatibility and seals for the selected construction.
Which Sizes and Rod Counts Are Available?
| Model reference | Drawers | Total rods | Overall dimensions (mm) |
|---|---|---|---|
| X04A / X04B | 4 | 28 | 344 × 277 × 510 |
| X06A / X06B | 6 | 42 | 344 × 277 × 745 |
| X12A / X12B | 12 | 84 | 344 × 277 × 1360 |
Dimensions are reference values; the order drawing and factory inspection report govern the supplied machine. Specify round or square connections, access side and withdrawal space. The X12 name appears in more than one family, so include the complete dimensions when requesting a quotation.
How Does This Compare with Other Drawer Magnets?
| Product | Published arrangement | Selection distinction |
|---|---|---|
| JINHONG JH-X | 7 rods per drawer; 28 / 42 / 84 total rods | A/B orientation and custom connections |
| Eriez Easy-to-Clean Grate-In-Housing | 1-inch tubes on 2-inch centres; one or multiple rows | Tube-scraper cleaning; manufacturer source |
The comparison describes published configurations, not a controlled performance test. Dimensions, cleaning mechanisms and acceptance conditions differ. Manufacturer sources checked on 25 October 2026; confirm current specifications with each supplier.
Does the 10 μm Reference Describe the Iron Being Removed?
No. The catalog uses a 10 μm material median-particle-size reference when distinguishing A (>10 μm) and B (≤10 μm) arrangements. This describes the processed material, not the minimum removable iron diameter. Moisture, cohesion and feed rate also influence selection; optional vibration and flexible isolation pads can be reviewed.
Which Magnetic Options and Utilities Need Confirmation?
The 3 rod options are JH-B standard, JH-L helical-field and JH-Z linear-field. Published drawer configurations list peak field values up to 16,000 GS; the agreed field, measurement position, sleeve and temperature must be specified for the order. Rod size and magnetic strength can be customized. Permanent magnets do not require excitation power; optional vibrators or other powered accessories have separate utility requirements.
For a quote, provide throughput, bulk density, particle-size distribution, temperature, contamination and installation dimensions. Compare rotary separation for bridging behaviour and JH-LX for an automated system.
Frequently Asked Questions
Does a 7-rod drawer contain seven rods in each layer?
No. The reference drawer has two layers containing three and four rods respectively: seven rods per drawer. Four such drawers contain 28 rods. Confirm the full assembly drawing because custom rod counts and dimensions may differ.
Can this drawer magnetic separator remove iron from powders finer than 10 μm?
The catalog B arrangement is intended for materials with median particle size at or below 10 μm. This is a feed-material reference, not an iron-removal limit. Provide the powder distribution, moisture and flow behaviour for selection and agree the separation acceptance test.
Is the JH-X08 the same product as the automatic JH-LX system?
No. JH-X08 is a drawer-separator family with guide rails and dust-control plates. JH-LX is the separately specified automatic system. The stated JH-LX iron-removal results must not be assumed for a JH-X or JH-X08 configuration.
Request a JH-X Configuration Review
Related applications and selection requirements
Review food-powder equipment selection and plastic granule processing to compare installation, material flow and cleaning requirements. The selected configuration must be assessed for the actual material and operating conditions.